Home > Altronix >

AL400ULM

AL400ULM


 
Price: $247.36
Price Per: EA

Quantity in Stock:1

Product Code: ALT_AL400ULM
Qty:

Description
 
Access Power Distribution Module w/ Power Supply/Charger, 5 PTC Class 2 Outputs, 12/24VDC @ 4A, FAI, 115VAC, BC300 Enclosure

AL400ULM multi-output access control power supply/charger is specifically designed for use with access control systems and accessories. This unit converts a 115VAC / 60Hz input into five (5) individually protected Class 2 Rated power limited 12VDC or 24VDC outputs. Each output will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.)supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay enables HVAC Shutdown, Elevator Recall or it may be used to trigger auxiliary devices.

Input
  • Input 115VAC / 60Hz, 3.5A.
  • Input fuse rated @ 5A/250V.
  • Fire Alarm Panel or Access Control System trigger inputs. N.O. or N.C. supervised trigger input and polarity reversal trigger input.
Output
  • 12VDC or 24VDC selectable outputs.
  • 12VDC @ 4A or 24VDC @ 3A supply current.
  • Burglar Alarm Applications:
  • 12VDC = 10VDC-13.2VDC;
  • 24VDC = 20VDC-26.4VDC.
  • Five (5) PTC protected Class 2 Rated power limited outputs, rated @ 2A (auto-resettable).
  • Output relay energizes when unit is triggered (form "C" contact rated 1A @ 28VDC).
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.
Battery Backup
  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.
Supervision
  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery supervision (form "C" contacts).
  • Battery presence supervision (form "C" contacts).
  • Power fail supervision relay (form "C" contacts).
Visual Indicators
  • AC input and DC output LED indicators (power supply board).
  • Red LEDs indicate condition of power outputs (multi-output board).
  • Power & input trigger LEDs (multi-output board).
Temperature
  • Operating: 0° C to 49° C (32° F to 120° F).
  • Storage: - 20° C to 70° C ( - 4° F to 158° F).
  • Relative Humidity 85% +/- 5%.
BTU/Hr (approx.):
  • 12VDC: 25 BTU/Hr.
  • 24VDC: 37 BTU/Hr.
System AC input VA requirement: 402.5VA.

Share your knowledge of this product. Be the first to write a review »