Skip to content
To take full advantage of this site, please enable your browser's JavaScript feature.
Learn how
Electronic Supply
Toggle Menu
Shop Our Categories
Toggle search
Cart
Search site
Submit search
Audio/Video
Adapters & Connectors
Belts
Cables
Intercoms
Microphones
Multimedia
Adapters
Controllers
Converters
Switches
PA System
Projector/Monitor Mounts
Speakers
Tubes
TV
Antennas
Preamplifiers
Rotors
Splitters
Video Adapters
Video Cables
Batteries & Chargers
Batteries
Chargers
Chemicals
Adhesives, Coatings & Sealants
Cleaning Products
Dusters
Flux / Flux Removers
Freeze
Lubricants
Solder / Desolder
Specialty Products
Tape
Under Carpet
Components
Accessories
Capacitors
Diodes & Rectifiers
Inductors
Integrated Circuits
Potentiometers
Resistors
Semiconductors
Computer/Office Products
Accessories
Adapters
Cables
USB
Connectors & Adapters
Adapters
Coax
Computer (DB Style)
Fiber
Miscellaneous
Molex
RF
Ribbon Connectors
Telecom
Terminal Strips
Under Carpet
Wago (Din Rail Connectors)
Wire Terminals
Fans & Accessories
Fans
Filters, Guards & Cords
Networking
Active
Media Converters
POE
Routers, Switches & Hubs
WiFi
Cable Management
Copper
Fiber
Passive (Jacks, Plates, Etc.)
Patch Cables - Copper
Patch Cables - Fiber
Under Carpet
Uniprise
Optoelectronics & Lighting
Lamps
LED Light Strips
LEDs
Power
Adapters & Transformers
Cables, Plugs & Cords
Circuit Breakers
Environmental
Flashlights
Fuses
Power Supplies & Accessories
Surge Protection & Power Strips
UPS
Racks, Boxes & Enclosures
Accessories
Project Boxes
Racks & Cabinets
Wall Mount
Relays & Switches
Relays
Switches
Timers
Security
Access Control
Accessories
Body Temp Devices
CCTV
Accessories
Cameras
Lenses
Recorders
Locks & Strikes
Media Converters
Sensors / Switches
Sirens, Horns & Buzzers
Thermographics
Telephone Accessories
Accessories
Passive (Jacks, Plates, Etc.)
Wire & Cords
Test and Measurement
Accessories
Cases
Bench Meters
Butt Sets
Circuit Voltage Testers
Clamp Meters
Coax/Twisted Pair
Environmental
Fiber
Multimeters
Network
Oscilloscopes
Panel Meters
Perfboard & Hobby Kits
Specialty Testers
Thermal Imaging
Tone & Probe
Tools & Hardware
Anti-Static
Cases
Crimping & Compression
Cutting Tools & Pliers
Hardware
Miscellaneous Hardware
Screws & Nuts
Magnifying Lamps
Marking / Identification
Misc Tools
Miscellaneous
Networking Tools
Punchdown Tools
Reference Manuals
Screwdrivers & Nutdrivers
Soldering Equipment
Tweezers
Wire & Cable
Accessories
Coax
Copper
Fiber
Networking Cable
Specialty Wire
Under Carpet
Wire Management
Cable Ties
Shrink Tubing
Gift Certificate
Suppliers Links
Click here for Suppliers
Additional Info
Business Documents
Corporate Brochure
Credit Application
MO Sales Tax Policy
MO Tax Form 149
Under Carpet Manuals
Under Carpet - How To
Under Carpet - Install
Under Carpet - Q&A
Line Card
Live Video
Promos
Tech Tips
Category Cable Differences
CCTV Ground Loops
LED Resistor Calculation
Surge Protection
TIA-568 Wiring Protocol
Voltage - Analog Cameras
What is a Varistor?
Who We Are
Nav Menu 4
Nav Menu 5
Nav Menu 6
Nav Menu 7
Nav Menu 8
Account
View Cart
Order Status
About Us
Contact Us
Help/FAQ
Shipping
Returns
Privacy Policy
Home
>
Altronix
>
AL600ULACM
Price:
$
353.14
Price Per:
EA
Quantity in Stock:
(Out of Stock)
Product Code:
ALT_AL600ULACM
Qty:
Email me when Back-In-Stock
Description
Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC @ 6A, FAI, 115VAC, BC400 Enclosure
Altronix AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Input 115VAC 60Hz rated @ 3.5A.
Power supply input options:
a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
Eight (8) Access Control System trigger inputs.
Input options:
a) Eight (8) normally open (NO) inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
Output
12VDC or 24VDC @ 6A supply current.
Eight (8) independently controlled outputs.
Output options:
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
b) Eight (8) form "C" 5A rated relay outputs
c) Any combination of the above.
Eight (8) auxiliary power outputs (unswitched)
Output ratings:
Fuses are rated @ 3.5A.
Filtered and electronically regulated outputs (built-in power supply).
ACM8 board main fuse is rated at 10A.
Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery and battery presence supervision (form "C" contact).
Features
Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
Short circuit and thermal overload protection.
AC fail supervision (form "C" contact).
Visual Indicators
Red LEDs indicate outputs are triggered (relays energized).
Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.
Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unitswitches over to battery backup (AC failure condition).
Battery fail and battery presence supervision (form "C" contact).
Temperature
Operating: 0ºC to 49ºC (32ºF to 120ºF).
Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).
Relative Humidity 85% +/- 5%.
BTU/Hr. (approx.):
12VDC: 37 BTU/Hr.
24VDC: 74 BTU/Hr.
Related Items
ST3
TP1650
AL600ULPD8
RBSN
Price:
$7.83
Price:
$22.04
Price:
$290.71
Price:
$11.24
TP2450
STRIKEIT2
ALTV248300UL
AL175UL
Price:
$22.04
Price:
$226.17
Price:
$226.64
Price:
$153.21
Share your knowledge of this product.
Be the first to write a review »